Place of Origin:
Guangdong, China
Brand Name:
Linke
Certification:
3C,UL,TPU,UL758,ROHS,REACH,CE,ISO9001-2015,ISO13485,IATF16949
Linke cable technology (DongGuan) Co. Ltd. concentrate on R&D and provide professional solutions to the Cable&Wire,especially for the different industry customers.It contains :
Linke Cable has diversified product development capabilities and technical capabilities to support diversified customer needs. We have obtained the following product authorization:UL 758,CCC,RoHs,REACH,CE; We have obtained the following quality management system:ISO 9001-2015(All products); ISO 13485(Medical apparatus and instruments),IATF 16949(Auto industry)
Independent Laboratory • Complete Testing Equipment • Full Quality Control
We test every product by strict standards to ensure superior quality and reliable performance.
We operate an independent quality testing laboratory with complete testing facilities and standardized procedures. Our full set of product testing standards covers all key performance and safety indicators. Through systematic and rigorous inspection, we effectively control product quality, reduce risks, and provide you with safe, stable and high-quality products you can trust.
| No. | Test Item | Test Condition | Test Requirement | Test Data | Result |
|---|---|---|---|---|---|
| 1 | Structure Inspection | 1. Comply with wire size table2. Minimum thickness ≥ 80% of average thickness | Comply with wire size table | Refer to test record | Pass |
| 2 | Thermal Shock | Wind the sample on an iron rod of specified size, place in an aging oven at specified temperature for 1 hour, cool the sample to room temperature for at least 30 minutes, then observe the sample | No cracks on the sample surface | No cracks | Pass |
| 3 | Heat Deformation | 1. Measure sample thickness (mark measurement position)2. Place sample and test fixture in aging oven for preheating at specified temperature for 1 hour3. Place sample under pressure column of test fixture for 1 hour4. Re-measure sample thickness at the same position | 1. Sample shall not be cracked by pressure column or expose conductor2. Thickness reduction ≤ 50% | Refer to test record | Pass |
| 4 | FT2 | Apply a standard flame at a height of 125mm once | 1. Flame shall not propagate along its length2. Flame shall not spread to nearby flammable materials | Refer to test record | Pass |
| 5 | Aging | 1. Take five sections of 200mm-long sheath2. Place specimens in aging oven at 158℃ for 168 hours3. After taking out specimens, place at room temperature 23±5℃ for 16 hours, then test elongation at break and tensile strength | 1. Elongation before aging ≥ 300%, elongation after aging ≥ 80% of that before aging2. Tensile strength before aging > 1.41kg/mm², tensile strength after aging ≥ 80% of that before aging | Refer to test record | Pass |
| 6 | Cold Bend | Store sample in low-temperature box at specified temperature for 4 hours, wind sample on iron rod of specified size with specified turns, complete winding within 30 seconds after sample is taken out of low-temperature box | No cracks on the sample surface | No cracks | Pass |
| 7 | Conductor Resistance | Measure resistance of one-meter core conductor with DC resistance meter | At 20℃, resistance of 8AWG ≤ 2.23Ω/km | Refer to test record | Pass |
High-quality flexible house wiring copper PVC electrical wire and cable available in various sizes including 1.5mm, 2.5mm, 6mm, and 20mm.
Single-conductor, thermoplastic insulation
| 1007 | 1330 | 1333 | 1591 | 1723 | 10064 | 10369 |
| 1015 | 1331 | 1569 | 1592 | 1901 | 10070 | 10483 |
| 1185 | 1332 | 1577 | 1672 | 10012 | 10269 |
Multiple-conductor, thermoplastic insulation
| 2095 | 2129 | 2468 | 2586 | 2725 | 20233 | 20280 | 20963 |
| 2103 | 2463 | 2517 | 2587 | 2835 | 20276 | 20549 | 21198 |
| 2104 | 2464 | 2576 | 2661 | 2919 | 20279 | 20886 | 21664 |
Single-conductor, thermoset insulation
| 3075 | 3173 | 3320 | 3386 | 3530 | 3689 | 30005 | |
| 3123 | 3212 | 3321 | 3398 | 3577 | 3702 | ||
| 3132 | 3266 | 3331 | 3512 | 3644 | 3817 | ||
| 3135 | 3271 | 3385 | 3529 | 3674 | 3886 |
The control cable can be produced according to the standard GB9330-1988, and can also be manufactured in accordance with other standards.
Suitable for electrical controlling equipment and instrument wiring, monitoring and controlling return circuits, electrical protection and measurement in power distribution units with rated voltage up to 450/750V AC.
As a leading cable supplier in China, Linke Cable has focused on R&D, production and marketing of wire and cable for over 10 years. We provide various cables and custom cable solutions worldwide, specializing in:
We use an engineer-to-engineer approach to develop better cables for customers and improve quality of life.
We are a professional manufacturer. We can control your order from beginning to end. Welcome to visit us - we'll pick you up in Shenzhen.
Samples are free for you. New clients are expected to pay for the courier cost.
Normally 100m. However, the cable is very heavy. You'd better order a suitable quantity to avoid high freight. Sea transportation is the best option.
It depends on your quantity. We can make a discount and afford the freight. Please contact us for details.
Yes, we can print your company name and even customize quality cards to promote your company.
Send your inquiry directly to us